Centrifugal pump EVN-130-3 (370W)
Article: EVN-130-3
| Mains voltage | 220 V |
| Power consumption | 370 W |
| Throughput capacity | 90 l/min |
| Maximum pressure | 23 m |
| Current | 2.5 A |
| Speed | 2900 rot/min |
| Connector connector | 25 mm |
| Suction depth | 8 m |
| Warranty | 12 month |
1. Copper winding:
The copper winding is resistant to overloads and can operate at a low power supply voltage of 160–220 V.
2. Brass impeller:
It does not rust. The water delivery volume does not decrease over time.
3. System and operating type:
The pump performs water lifting and water supply. It is mainly installed in microclimate systems, and if it is connected to a water system, a 10-bar pressure switch must be installed. It can supply 2–3 water points, and when the taps are closed, the pump automatically turns off.
4. Pressure switch (relay):
The pump does not have an automatic shut-off system by default, but if a 10-bar pressure switch is installed, it can regulate water pressure and adapt to the water points.
5. Service (Warranty):
If any defects are found during the warranty period, free service and maintenance will be provided.
6. Dry-run protection:
If there is no water in the main pipeline, the pump will continue to run because it has NO dry-run protection. In this case, the pump must be disconnected from the power supply (unless a 10-bar pressure switch is installed).
1. Copper winding:
The copper winding is resistant to overloads and can operate at a low power supply voltage of 160–220 V.
2. Brass impeller:
It does not rust. The water delivery volume does not decrease over time.
3. System and operating type:
The pump performs water lifting and water supply. It is mainly installed in microclimate systems, and if it is connected to a water system, a 10-bar pressure switch must be installed. It can supply 2–3 water points, and when the taps are closed, the pump automatically turns off.
4. Pressure switch (relay):
The pump does not have an automatic shut-off system by default, but if a 10-bar pressure switch is installed, it can regulate water pressure and adapt to the water points.
5. Service (Warranty):
If any defects are found during the warranty period, free service and maintenance will be provided.
6. Dry-run protection:
If there is no water in the main pipeline, the pump will continue to run because it has NO dry-run protection. In this case, the pump must be disconnected from the power supply (unless a 10-bar pressure switch is installed).